Cooling at 95F¹
Maximum Capacity Btu/h:
22,000
Rated Capacity Btu/h:
18,000
Minimum Capacity Btu/h:
5,200
Maximum Power Input W:
2,150
Rated Power Input W:
1,280
Moisture Removal Pints/h:
3.4
Sensible Heat Factor-:
0.79
Power Factor [208V / 230V] %:
97 / 97
Heating at 47F²
Maximum Capacity Btu/h:
27,400
Rated Capacity Btu/h:
21,600
Minimum Capacity Btu/h:
6,800
Maximum Power Input W:
4,000
Rated Power Input W:
1,680
Power Factor [208V / 230V] %:
97 / 97
Heating at 17F³
Maximum Capacity Btu/h:
18,200
Rated Capacity Btu/h:
13,700
Maximum Power Input W:
2,900
Rated Power Input W:
1,460
Heating at 5F⁴
Maximum Capacity Btu/h:
15,200
Maximum Power Input W:
2,470
Heating at -5F⁶ Maximum Capacity Btu/h:
11,720
Heating at -10F⁷ Maximum Capacity Btu/h:
10,330
Efficiency
COP at 17°F at Maximum Capacity³:
1.82
COP at 5°F at Maximum Capacity⁴:
1.8
COP at -5°F at Maximum Capacity⁶:
1.56
COP at -10°F at Maximum Capacity⁷:
1.46
ENERGY STAR® Certified:
Yes
Electrical
Voltage, Phase, Frequency V AC / V AC, ø, Hz:
208 / 230, 1, 60
Guaranteed Voltage Range V AC:
187 - 253
Voltage: Indoor - Outdoor, S1-S2 V AC:
230
Voltage: Indoor - Outdoor, S2-S3 V DC:
24
Short-circuit Current Rating [SCCR] kA:
5
Recommended Fuse/Breaker Size (Outdoor) A:
50
Recommended Wire Size [Indoor - Outdoor] AWG:
14
Indoor Unit
Airflow Rate at Cooling, Dry CFM:
324, 392, 454, 530, 650
Airflow Rate at Cooling, Wet CFM:
292, 353, 408, 477, 585
Airflow Rate at Heating, Dry CFM:
344, 392, 454, 530, 672
Sound Pressure Level [Cooling] dB (A):
28, 33, 38, 44, 49
Sound Pressure Level [Heating] dB (A):
28, 34, 39, 43, 48
Drain Pipe Size O.D. inch [mm]:
5/8 [15.88]
Dual Barrier Coating on Heat Exchanger:
Yes
External Finish Color:
Munsell 0.7PB 9.2/0.4
Unit Dimensions (W x D x H) inch x inch x inch:
43-5/16 x 10-1/8 x 12-13/16
[mm x mm x mm]:
[1,100 x 257 x 325]
Package Dimensions (W x D x H) inch x inch x inch:
45-1/2 x 15-1/2 x 13-1/2
[mm x mm x mm]:
[1,160 x 400 x 340]
Unit Weight lbs [kg]:
37 [16.50]
Package Weight lbs [kg]:
42 [18.80]
IDU Operating Temp. Range
Cooling Intake Air Temp [Maximum / Minimum] °FDB, °FWB / °FDB, °FWB:
90, 73 / 67, 57
Heating Intake Air Temp [Maximum / Minimum] °FDB:
80 / 70
ODU Operating Temp. Range
Cooling Intake Air Temp [Maximum / Minimum*] °FDB:
115 / 14
Cooling Thermal Lock-out / Re-start Temperatures** °FDB:
-1 / 3
Heating Intake Air Temp [Maximum / Minimum] °FDB, °FWB / °FDB, °FWB:
75, 65 / -5, -6
Heating Thermal Lock-out / Re-start Temperatures** °FDB:
-14 / -4
Refrigerant
Pre-Charged Refrigerant Amount lbs, oz:
3, 12
Maximum Pre-Charged Piping Length ft [m]:
50 [15]
Additional Refrigerant Charge Per Additional Piping Length oz/f:
0.22
Piping
Gas Pipe Size O.D. [Flared] inch [mm]:
1/2 [12.70]
Liquid Pipe Size O.D. [Flared] inch [mm]:
1/4 [6.35]
Maximum Piping Length ft [m]:
100 [30]
Maximum Height Difference ft [m]:
50 [15]
Maximum Number of Bends:
10