Description
15,000 BTU Packaged Air Terminal Air Conditioner
The DHP153J35BA is for residential and commercial use with 208 / 230 volt electricity. This unit offers 14,500 / 14,700 BTUs of cooling power, 13,200 / 13,500 BTU heat pump capacity and a 3.5 kW electric heater, providing approximately 8,900 / 10,900 BTUs of electric backup heat. It also includes a 20 amp power cord. The Distinctions by Amana DHP153J35BA PTAC features an EER of 10.6. It use R32 refrigerant. R32 is up to 12% more efficient than R410A, resulting in lower Global Warming Potential (GWP). The lower the GWP, the better for the environment.
Specifications
Overview
Type of Through-the-Wall:
42" PTAC
Sleeve Required for Install:
Yes
Fits Sleeve Size (in.):
42
Dehumidification (pts/hr):
4.33
Heat Type:
Heat Pump with Back-Up Electric
Cooling BTUs (@208V):
14500
Cooling Amps (@208V):
7.4
Cooling Watts (@208V):
1370
Electric Heat Strip Size (kW - @208V):
2.9
Electric Heating BTUs (@208V):
8900
Electric Heating Amps (@208V):
13.7
Electric Heating Watts (@208V):
2897
Heat Pump BTUs (@208V):
13500
Heat Pump Heating Amps (@208V):
6.4
Heat Pump Heating Watts (@208V):
1120
Cooling BTUs (@230V):
14700
Cooling Amps (@230V):
5.3
Cooling Watts (@230V):
1040
Electric Heat Strip Size (kW - @230V):
3.5
Electric Heating BTUs (@230V):
10900
Electric Heating Amps (@230V):
15.3
Electric Heating Watts (@230V):
3500
Heat Pump BTUs (@230V):
13500
Heat Pump Heating Amps (@230V):
6.0
Heat Pump Heating Watts (@230V):
1170
Control Type:
Electronic/Digital
Connectivity:
Not WiFi Compatible
Net Weight (lbs.):
113.54
Electrical Requirements
Circuit Breaker Size (Amps):
20
Dimensions
Features
Vent placement
Energy Saver Mode
Fresh air intake
- Washable, front-access filters for easy maintenance
Control
- Requires a wired wall thermostat; no built-in digital controls, no Wi-Fi, no remote, no sleep mode, no 24-hour timer.
Automatic Emergency Heat
- The electric backup activates if the heat pump can’t meet heating demand or if it fails
Evaporator Freeze Protection
- Shuts off compressor and runs fan if the evaporator gets too cold, then restores once safe
Condensate Dispersion System
- Throws excess moisture onto the outdoor coil for faster evaporation and better performance.
California residents see