Free Shipping

Soleus SGPTAC12HPDA

12,000 BTU Packaged Terminal Air Conditioner with Heat Pump, Electric Heat Backup, 10.5 EER, R-410A Refrigerant, 3 Fan Speeds and 24 Hours Timer

Your Price: $728.00

Qty:

Price Match Policy Price Match Policy
Printer Friendly Page Print
Share this item:

Companion Products, Options, and Accessories

Soleus SGPTAC12HPDA

This item

Add selected items to cart

Total price: 0

Additional Options

Add

Grille

(SGPTACG)
+ $22.00 
Add

Metal Sleeve

(SGPTACS)
+ $78.00 
Description
Innovative Products For A More Comfortable Home
At Soleus Air they design their products with their customers in mind. They don't simply make home comfort products; they make better home comfort products. Their focus on quality, style and ease-of-use challenges them to design products that look great while creating a more comfortable living environment. Available at AJ Madison.

How To Choose A Room Air Conditioner
Compared to large capacity central units, room air conditioners have several advantages. The initial cost of a room air conditioning unit is significantly lower than the cost of central air. Because room air conditioners are designed for cooling small spaces, operating costs are reduced. And, room air conditioners can provide personalized temperature and humidity controls that central systems cannot.

Calculating Cooling Capacity
Cooling capacity is the critical factor in properly selecting a room air conditioner. Cooling capacity is measured in British Thermal Units (BTUs) and typical models will range in capacity from 5,000 BTUs to 28,500 BTUs.

Choosing an undersized unit will overwork the unit and it will not cool properly. Choosing an over-sized unit will cost more to buy and operate and it will not dehumidify properly.

We can help you to calculate capacity. Be prepared to provide specific information on:
  • Room Dimensions
  • A simple floor plan to show the location of doors and north-facing windows
  • The number of people it will serve
  • Sources of heat such as lamps, TV and appliances
  • An explanation of what's above the intended room
  • Your insulation provisions

Cooling Capacity by Room Size
Measure the length and width of the area to be cooled. Multiply the length by the width to determine square footage or square meters. Locate the room size in the chart below to select the appropriate BTUs. Then use the product information to select the unit for your room. When cooling rooms with uninsulated ceilings, great rooms, or southern or western sun exposures - step up to the next BTU size.

Room SizeBTU
Sq. Ft.Sq. m
15014 up to 5,000
16515 5,200
216206,000
350338,000
425399,000
5004610,000
6406014,00
9008415,100
1,11010318,000
1,17010918,500
1,43513322,000
1,67215425,000
1,96018228,500


Air Conditioner Tips
Air flow - Keep air filters clean. Do not block air flow areas.

Roomside view - J-models feature concealed power cord storage, this eliminates excessive cord exposure when receptacle is located close to unit.

Wall Opening For RAB46/47/48 Cases
A finished opening of 26 1/8" x 15 3/4", clear of intrusions, is required. Keep clearance of 4" from side walls. Brick veneer or frame walls should have wood studding surrounding case to provide firm anchoring with screws. Case can be fastened directly to brick or block walls with screws sunk in lead expansion shields. NOTE: units should be caulked on all four sides of case to the building exterior to assure building integrity.
Energy Info
This air conditioner has an Energy Efficiency Rating of 10.5 and has an estimated yearly operating cost of $95.06.

Your operating costs will depend on your utility rates and use. The estimated yearly operating cost is based on the 2011 national average cost of $.1109 cents per kWh for electricity and an estimated number of operating hours of 750 hours.

For more information, visit www.ftc.gov/appliances.
Specifications
Specifications
BTU: 12,000 BTU
EER: 10.5/10.7
Dehumidification: 64.8 Pints/Day
Airflow (High/Med/Low): 550/520/490 CFM
Noise Level (High/Med/Low): 53/52/51 dB(A)
Refrigerant: R410A
Voltage: 230/208V; 60HZ
Amps - Cooling: 5.3/5.1 Amps
Amps - Heating: 4.7/4.5 Amps
Amps - Electric Heat: 12.2/13.2 Amps
Watts - Cooling: 1,120/1,120 Watts
Watts - Heating: 990/1,010 Watts
Watts - Electric Heat: 2,452/3,000 Watts
Dimensions and Weights
Overall Width: 42"
Overall Depth: 21 3/4"
Overall Height: 16"
Product Weight: 111 Lbs.
Shipping Weight: 138 Lbs.
Features
  • 12,000 BTU
  • 10.5/10.7 EER
  • Heat and Cool Function
  • Digital Display
  • 3 Fan Speeds
  • 24 Hours Timer
  • Intelligence
  • Your Premium unit has an on board computer that utilizes real time diagnostics to prolong the life of your unit.
  • Memory
  • If power is lost, all of the control settings (setpoint, mode, fan speed, on/off and configuration) are remembered.
  • So when power is restored, the unit will start back up in the mode (and configuration) it was in, when power was lost.
  • Premium Sound
  • Random Compressor Restart
  • Compressor Protection
  • Automatic Room Freeze Protection
  • Automatically will keep the temperature in the room from getting too cold, where water pipes might freeze.
  • Automatic Defrost Protection (For Heat Pump Models Only)
  • When the outdoor temperature gets too cold (approx. 35°F) and the unit can no longer effectively heat with the compressor, the unit will automatically switch to electric heating.
  • The unit will then heat with electric heat until the outside temperature rises enough (approx. 40°F), so the compressor can be used again.
  • Automatic Quick Warm-Up (For Heat Pump Models Only)
  • If the room temperature falls to 5°F below the set point temperature, the reverse cycle heat is shut off.
  • And the electric strip heat is turned on for one cycle, until heating is satisfied.
  • LED Indicators and Buttons
  • Configure Fan To Optimize Selected Application
  • Unit can be optimized to selected application by configuring the fan to run in continuous mode or cycle on and off with the compressor and electric heater (can be different for both heating and cooling modes).
  • Unit Configuration
  • There are many different configuration possibilities, through both dip switches and the digital keypad, that allow you to configure the unit for your exact application.
  • °F or °C
  • The unit can display in either °F or °C.
  • Indoor Temperature Sensor Biasing
  • Optimize the room temperature sensor reading to your exact application (one for cooling and another for heating).
  • Emergency Heat (For Heat Pump Only)
  • Disable the compressor during heating mode operation (heat only with Electric Heat).
  • Display Setpoint Or Room Temperature
  • The unit can be configured to display the room temperature OR setpoint only, during heating and cooling modes.
  • Limit The Setpoint Range
  • The unit can be configured to limit the controlling setpoint range.
  • The display will always show the complete setpoint range, but the controlling setpoint will be limited to the configured minimum and maximum setpoint selected.
  • Energy Management
  • Sometimes known as Front Desk Control, an input is provided so that the unit can be manually disabled from a different location.
Info and Guides

Adobe Acrobat FileOwners Manual

You will need Adobe Acrobat Reader to view and print pdf files

Adobe Reader
Product Reviews
Items to Compare

Quick LookQuick Look

Quick Specs
Quick Specs

Dimensions

  • Width : 42"
  • Depth : 21 3/4"
  • Height : 16"

Features

  • Type : Wall
  • Chassis Type : Thru the Wall
  • Wall Sleeve Included : No
  • Cooling Capacity (BTU) : 12,000 BTU
  • Maximum Cooling Amps : 5.3 Amps
  • Maximum Cooling Watts : 1,120 Watts
  • Maximum Heating Amps : 4.7 Amps
  • Maximum Heating Watts : 990 Watts
  • Heat : Heat Pump with Electric Heat Backup
  • CFM Room Circulation : 550 CFM
  • Energy Efficiency Rating : 10.5
  • Control Type : Digital
  • Remote Control Included : No
  • PTAC : Yes

Technical Details

  • Energy Star Rated : No
  • ADA Compliant : No
Are you a builder

© 2014, AJ Madison Inc. or its affiliates