LG Art Cool Mirror LA120HSV2

11,200 BTU Single Zone Wall-Mount Ductless Split System with 13,300 BTU Heat Pump, 20.0 SEER, 12.5 EER, R-410A Refrigerant and Inverter Compressor (LAN120HSV2 Indoor / LAU120HSV2 Outdoor)

Your Price: $1,269.00

Qty:

Price Match Policy Price Match Policy
Printer Friendly Page Print
Share this item:

Financing Available! Learn more now.
As low as
$105.75/month 1
Financing Available! Learn more now. Learn More >

Companion Products, Options, and Accessories

LG LA120HSV2

This item

Add selected items to cart

Total price: 0

Additional Options

Add

V-Net Control Integration Accessory

(PMNFP14A0) preview
+ $153.00 
Add

Multi-V Wired 7-Day Programmable Thermostat

(PREMTB10U) preview
+ $183.00 
Description
Art Cool Mirror Mini-Split Systems
Art Cool Mirror mini-split systems featuring sleek, mirror-finished indoor units, and outdoor units with energy-efficient Inverter technology. Choose from models with capacities from 9,000 to 24,000 BTU/h.

Single-zone systems that feature an innovative design and high efficiency levels. The mirrored wall-mounted indoor units allow for easy installation, while the majority of systems in this line achieve Energy Star and tax credit qualifications.

Welcome To LG
LG Electronics USA Commercial Air Conditioning business is a leading player in the global air conditioning market, manufacturing both commercial and residential air conditioners and providing total sustainability and building management solutions. From consumer units to commercial air conditioning systems, LG provides a wide range of innovative products for heating, ventilating and air conditioning.

About Duct-Free Systems
A duct-free system, also known as a "split" air conditioner system, is made up of or includes two components: an indoor unit to deliver conditioned air to the room, and an outdoor unit located outside of the house. Compact refrigerant lines run between the two units, eliminating the need for bulky ductwork. Duct-free systems are ideal for older homes that have no ductwork, room additions, or areas in homes that just never seem to be the right temperature or are never comfortable.

LG duct-free systems are available in a range of sizes and styles - including systems that can heat and cool multiple rooms with a single outdoor unit to fit almost any need. The indoor units are available in many different types to fit with the look and feel of your home.

How To Choose A Room Air Conditioner
Compared to large capacity central units, room air conditioners have several advantages. The initial cost of a room air conditioning unit is significantly lower than the cost of central air. Because room air conditioners are designed for cooling small spaces, operating costs are reduced. And, room air conditioners can provide personalized temperature and humidity controls that central systems cannot.

Calculating Cooling Capacity
Cooling capacity is the critical factor in properly selecting a room air conditioner. Cooling capacity is measured in British Thermal Units (BTUs) and typical models will range in capacity from 5,000 BTUs to 28,500 BTUs.

Choosing an undersized unit will overwork the unit and it will not cool properly. Choosing an over-sized unit will cost more to buy and operate and it will not dehumidify properly.

We can help you to calculate capacity. Be prepared to provide specific information on:
  • Room Dimensions
  • A simple floor plan to show the location of doors and north-facing windows
  • The number of people it will serve
  • Sources of heat such as lamps, TV and appliances
  • An explanation of what's above the intended room
  • Your insulation provisions

Cooling Capacity by Room Size
Measure the length and width of the area to be cooled. Multiply the length by the width to determine square footage or square meters. Locate the room size in the chart below to select the appropriate BTUs. Then use the product information to select the unit for your room. When cooling rooms with uninsulated ceilings, great rooms, or southern or western sun exposures - step up to the next BTU size.

Room SizeBTU
Sq. Ft.Sq. m
15014 up to 5,000
16515 5,200
216206,000
350338,000
425399,000
5004610,000
6406014,00
9008415,100
1,11010318,000
1,17010918,500
1,43513322,000
1,67215425,000
1,96018228,500


Air Conditioner Tips
Air flow - Keep air filters clean. Do not block air flow areas.

Roomside view - J-models feature concealed power cord storage, this eliminates excessive cord exposure when receptacle is located close to unit.

Wall Opening For RAB46/47/48 Cases
A finished opening of 26 1/8" x 15 3/4", clear of intrusions, is required. Keep clearance of 4" from side walls. Brick veneer or frame walls should have wood studding surrounding case to provide firm anchoring with screws. Case can be fastened directly to brick or block walls with screws sunk in lead expansion shields. NOTE: units should be caulked on all four sides of case to the building exterior to assure building integrity.
Energy Info
This air conditioner has an Energy Efficiency Rating of 12.5 and has an estimated yearly operating cost of $74.52.

Your operating costs will depend on your utility rates and use. The estimated yearly operating cost is based on the 2011 national average cost of $.1109 cents per kWh for electricity and an estimated number of operating hours of 750 hours.

For more information, visit www.ftc.gov/appliances.
Specifications
System Model
System Model: LA120HSV2
Indoor Model: LAN120HSV2
Outdoor Model: LAU120HSV2
Performance
Capacity - Cooling: 11,200 BTU
Capacity - Heating: 13,300 BTU
EER: 12.5
SEER: 20.0
HSPF: 11.0
Air Circulation (H/M/L): 350/280/210 CFM
Fan Speeds: 6/Auto/Chaos
Dehumidification: 3.0 Pts/Hr
Indoor dB(A): 39/33/24 dB(A)
Outdoor dB(A): 45 dB(A)
Warranty: 3 Years Parts, 5 Years Compressor
Electrical
Rated Voltage Outdoor: 230/208-60-1
Rated Voltage Indoor: 230/208-60-1
Rated Amps: 8.5 Amps
Min. Circuit Ampacity (MCA): 10
Max. Overcurrent Protection (MOP): 15
Refrigerant Line Specifications
Pipe Size - Liquid: 1/4"
Pipe Size - Suction: 3/8"
Additional Refrigerant: 0.22 Oz./Ft.
Max. Pipe Length: 65 Ft.
Max. Elevation: 32 Ft.
Thermostat Range
Cooling: 64° - 86°F
Heating: 60° - 86°F
Indoor Dimensions and Weights
Overall Width: 35 1/4"
Overall Depth: 8 1/16"
Overall Height: 11 1/4"
Weight: 24.3 Lbs.
Outdoor Dimensions and Weights
Overall Width: 30 5/16"
Overall Depth: 11 5/16"
Overall Height: 21 7/16"
Weight: 77.2 Lbs.
Features
  • Features
  • Inverter (Variable Speed Compressor)
  • Energy Saving
  • R-410A Refrigerant
  • Gold Fin Anti-Corrosion
  • Self-Cleaning Indoor Coil
  • Cooling/Heating/Fan Mode
  • Jet Cool/Jet Heat
  • Chaos Wind
  • 4-Way Auto Swing
  • Ultra Quiet Operation
  • Sleep Mode
  • Dehumidifying Mode
  • Auto Restart
  • Auto Changeover
  • Built-In Low Ambient Standard, Down To 14°F (Cooling Mode)
  • 24-Hour On/Off Timer
  • Condensate Sensor Connection
  • Plasma Air Purifying System
  • Interior Unit Includes
  • Wall Unit
  • Installation Plate and Hardware
  • Remote Control, Batteries, Holder and Holder Hardware
  • Installation Manual
  • Exterior Unit Includes
  • Exterior Unit
  • Exterior Unit Has Sufficient Refrigerant For Charging Indoor Coil And A 41 Ft. Line Set (Line Set Not Included)
  • ETL# : 3091879
  • Available At AJ Madison
  • www.ajmadison.com
Info and Guides

Adobe Acrobat FileCatalog

You will need Adobe Acrobat Reader to view and print pdf files

Adobe Reader
Product Reviews
Rated 4 out of 5 by 1 reviewer.
Rated 4 out of 5 Supplemental Cooling Have installed two of these units as supplemental cooling for office and bedroom. Allows for cooler temps in these areas without having to cool the whole house. Very efficient and very quiet. 6/27/13
1-1 of 1
Warranty Info

Warranties on mini split air conditioners only include parts and do not include labor. The licensed HVAC Technician who installs your air conditioner should always provide you with a labor warranty (preferably for at least a full year to compliment the manufacturers' parts warranty).

AJ Madison will only finalize a Mini Split (Ductless Split System) purchase with an authorized HVAC Technician. AJ Madison recommends the installation of a mini-split system to be performed by a trained and qualified HVAC technician with the proper knowledge and background. A trained technician will be able to judge the best location for the air handling (evaporator) unit and also the correct size for the area the unit will heat and/or cool. For assistance with all your technical needs please contact our technical department at hvactechsupport@ajmadison.com.

Should you experience an issue during the installation or the initial startup of a unit please do not contact the manufacturer. You should have the technician that installed your system contact either AJ Madison or the manufacturer. We cannot accept any service or warranty calls from anyone but a licensed HVAC technician. We have a full technical support team available to help you throughout the installation process.

AJ Madison, Inc. cannot be held liable for improper installation and operation of any product purchased from our company. Should a warranty issue arise in which parts will need to be replaced, an installation receipt will be required along with your AJ Madison sales receipt. Failure to provide a receipt or invoice may result in the warranty not being honored.

Items to Compare

Quick LookQuick Look

Quick Specs
Quick Specs

General

  • AC System Type : Mini Split
  • Component Type : System
  • Operation : Cooling with Heat Pump
  • Min No. of Connectible Indoor Units : 1
  • Max. No of Connectible Indoor Units : 1
  • No. of Rooms : 1
  • Indoor Unit Placement Type : Wall Mount
  • Wireless Remote Control(s) Included : Included
  • Wired Remote Control(s) Included : Optional
  • No. of Remote Controls : 1

Capacity

  • Heating Capacity (BTU/h) : 13,300 BTU
  • Cooling Capacity (BTU/h) : 11,200 BTU

Electrical Data

  • Power Source V / Hz / Ø : (208/230/60/1)

Performance

  • Energy Star Certified : Yes
  • SEER (Seasonal Energy Efficiency Rating) : 20
  • EER (Energy Efficiency Rating) : 12.5
  • HSPF (Heat Seasonal Performance Factor) : 11
  • Airflow Rate Medium (CFM) : 350 CFM

Refrigeration System

  • Refrigerant Type : R-410A
  • Compressor Type : Inverter
  • Max. Line Length (ft.) : 65

Features

  • Low Ambient Operation : Yes
  • No. of Fan Speeds : 6

Technical Details

  • ADA Compliant : No
  • Voltage : 230/208 Volts

Warranty Terms

  • Indoor Unit Parts (Yrs) : 3
  • Compressor (Yrs) : 5

Dimensions & Weights

  • Net Weight (Lbs.) : 101.5 lb.
Are you a builder