Free Shipping

Panasonic KE24NKU

24,200 BTU Single Zone Wall-Mount Ductless Split System with 29,000 BTU Heat Pump, R-410A Refrigerant, Low Ambient and Wireless Remote Control (CSKE24NKU Indoor / CUKE24NKU Outdoor)

Price Match Policy Price Match Policy
Printer Friendly Page Print
Share this item:

Additional Options

Add

Mounting Bracket For Outdoor Unit

(BS600) preview
+ $109.00 
Description
The Global Trusted Air Conditioning Brand
53 years since its establishment, Panasonic Air Conditioning Group has grown into a global company. Through continuous quest for product innovations, the Group has evolved from manufacturing Compressor to providing Comprehensive Air Conditioning solutions. This has earned Panasonic, the reputation as the trusted brand for superior quality and reliable products in the industry. Available at AJ Madison.

Every Building Lives
When you think about a building as a living space, everyone involved lives better. From design to installation to operation, Panasonic lives for the living inside. Their line of conditioning solutions breathes life into structures big and small. With 25 years of experience in the U.S., they are consistently building new ideas to help build your business. By delivering multi-zone options, space-saving and environmentally friendly designs, their solutions are evolving, improving solutions.

Single Split System - Wall Mounted Heat Pumps
Panasonic's Ductless Split Heat Pump products offer wide versatility in solving your cooling and heating requirements for a single or multiple rooms. The Indoor unit (evaporator) is mounted inside the room, enclosed in a handsome space saving cabinet. It is connected to the outdoor unit (condenser) via refrigerant lines and inter-unit wiring through a 3-1/2" opening in the wall. Since no ductwork is required, installation is simple, fast and efficient. The indoor unit has been uniquely designed to provide Whisper Quiet operation while delivering comfort throughout the room(s). Panasonic Ductless Split Systems bring together sleek styling in wall, duct or ceiling mounted systems, with whisper quiet operations, quality and reliability you can count on.

A ductless split unit must be installed by a licensed HVAC (Heating Ventilation Air Conditioning) contractor.

Installation and Warranty Info
AJ Madison recommends the installation of a Ductless Split System to be done by a trained and qualified HVAC technician with the proper knowledge and background. A trained technician will be able to judge the best location for the air handling (evaporator) unit and also the correct size for the area it has to cool. For assistance with all your technical needs please contact our technical department at hvactechsupport@ajmadison.com.

Note: AJ Madison will only finalize a Mini-Split (Ductless Split System) purchase with an authorized HVAC Technician.

Should you experience an issue during the installation or the initial startup of the unit please do not contact the manufacturer. You should have the technician that installed the units contact either AJ Madison or the manufacturer. We cannot accept any service or warranty calls from anybody but a licensed HVAC technician. We have full technical support team available to help you throughout the installation process.

AJ Madison, Inc. cannot be held liable for improper installation and operation of any product purchased from our company. Should a warranty issue arise where parts will need to be replaced, an installation receipt will be required along with your AJ Madison sales receipt. Failure to provide a receipt or invoice may result in the warranty not being honored.

Note: Warranties on mini split air conditioners only include parts and do not include labor. The licensed HVAC Technician who installs your air conditioner should always provide you with a labor warranty (preferably for a full year to compliment the manufacturers' parts warranty).
Specifications
Technical Specifications
Type: Wall Mounted
Unit: Heat Pumps
Indoor Unit: CS-KE24NKU
Outdoor Unit: CU-KE24NKU
Performance and Electrical Ratings
Capacity Cooling (BTU/H): 24,200 (4,000 ~ 24,200)
Capacity Heating (BTU/H): 29,000 (4,400 ~ 29,000)
Moisture Removal - High: 4.89 Pints/H
Dry Air Flow - High: 659 CFM
Dry Air Flow - Medium: 571 CFM
Dry Air Flow - Low: 494 CFM
SEER - Cooling: 17
EER - Cooling: 9.8
HSPF - Heating: 8.5
Power Supply V, Phase, Hz: 230/208V, 1PH, 60Hz
Running Amps - Cooling - A: 10.8/12.1 (1.3 ~ 12.1)
Running Amps - Heating - A: 12/13.5 (1.3 ~ 13.5)
Power Input - Cooling - W: 2,460/2,460 /(280 ~ 2,460)
Power Input - Heating - W: 2,490/2,490 /(290 ~ 2,490)
Back-Up Heater: N/A
Fuse or Circuit Breaker Capacity - A: 20
Features
Controls: Microprocessor
Low Ambient Control: Built-In 0°F
Wireless Remote Controller: Included
Wired Remote Controller (Optional): CZ-RD515U and CZ-RC515U
Fan Speeds: Hi / Me / Lo and Auto
Timer: 1 Hr OFF and 24-Hr Program
Air Deflection - Horizontal: Manual
Air Deflection - Vertical: Automatic
Air Filter: Washable
Refrigerant: R-410A
Refrigerant Control: Electric Expansion Valve
Operation Sound - Indoor (Hi / Me / Lo/ Qt): 47 / 44 / 41 / 30 dB-A
Operation Sound - Outdoor (Hi): Indoor Unit: 55, Outdoor Unit: 56 dB-A
Refridgerant Piping - Type: Flare
Refridgerant Piping - Discharge: 1/4"
Refridgerant Piping - Suction: 5/8"
Refridgerant Pipe Length: Max. 100 Ft.
Elevation Difference - Outdoor Above: Max. 50 Ft. (This is maximum elevation difference when the indoor unit is located above the outdoor unit)
Elevation Difference - Outdoor Below: Max. 50 Ft. (This is maximum elevation difference when the indoor unit is located above the outdoor unit)
Dimensions and Weights
Indoor Unit - Width: 41 15/16"
Indoor Unit - Depth: 8 19/32"
Indoor Unit - Height: 11 23/32"
Indoor Unit - Net Weight: 26.5 Lbs.
Outdoor Unit - Width: 35 7/16"
Outdoor Unit - Depth: 12 19/32"
Outdoor Unit - Height: 29 1/8"
Outdoor Unit - Net Weight: 130.1 Lbs.
Features
  • Microprocessor-Controlled Operation
  • Microprocessor control ensures that the temperature and humidity levels in the room are always comfortable.
  • Wireless Remote Control
  • Panasonic's infrared Remote Control with and easy to read LCD Display, gives the user the capability to adjust & set:
  • Temperature.
  • Sweep (louver control).
  • Fan speeds.
  • Timer and more, for complete automatic operation.
  • Self-Diagnosing Function
  • Details of previous warnings are stored and can be verified on the liquid crystal display.
  • This makes it easier to diagnose malfunctions, greatly reducing service labor. (Wired remote controller)
  • Dry Mode
  • By coupling compressor and fan operation, intermittent operation can be precisely controlled according to room temperature, so that air is efficiently dehumidified.
  • 3 Fan Speeds and Automatic Fan Operation
  • Convenient microprocessor control automatically adjusts fan speed to High, Medium or Low.
  • According to room temperature to maintain a comfortable airflow throughout the room.
  • Air Sweep Control
  • The air sweep function moves the louver up and down in the air outlet, directing air in a "sweeping" motion around the room and providing comfort in every corner.
  • Louver Control
  • Louver can be manually set to the desired angle by remote control.
  • Automatic Heating and Cooling Changeover
  • After setting the temperature and functions you desire, just relax.
  • If the room temperature is higher than the set temperature, cooling operation begins.
  • If the room temperature is lower than the set temperature, heating operation begins.
  • During normal thermostat cycle operation, cooling and heating operations automatically change in accordance with set temperature, time and room temperature.
  • Night Setback Mode For Cooling and Heating
  • Cooling and DRY Mode:
  • With the Night Setback Mode, the air conditioner automatically raises the setting temperature 2°F after 30 minutes, and then another 2°F after the next 30 minutes.
  • Heating Mode:
  • With the Night Setback Mode, the setting temperature is automatically lowered 4°F after 30 minutes, and then another 4°F after the next 30 minutes.
  • This saves energy without sacrificing comfort and is ideal for gentle cooling and heating.
  • Hot Start Heating System
  • Right from the start, air is warm and comfortable.
  • The Hot Start Heating System prevents any cold blasts at the beginning while the heat pump is warming up. (Heat pump unit only)
  • 24-Hour Clock with ON/OFF Program Timer
  • The remote control unit allows you to set a wide variety of timer-based operations.
  • Such functions include automatic ON/OFF with a timer setting, same time ON/OFF every day, ON timer, OFF timer and Combination timer.
  • 1-Hour OFF Timer
  • When this button is pushed either while the unit is operating or while it is stopped, the unit will operate for one hour and then switch off automatically.
  • Automatic Restart Function After Power Failure
  • This feature allows the system to automatically resume operation at its preset program, after power is restored from a power failure.
  • Electric Refrigerant Control Valve
  • The circulation volume of the refrigerant is controlled by a pulse type electric control valve.
  • In order to attain optimum efficiency, when the power is switched ON, the opening degree of the electric control valve is controlled between 90 and 480 steps.
  • R-410A
  • Quiet Mode
  • LOW, low fan speed for extra quiet operation.
  • Available at AJ Madison.
  • www.ajmadison.com
Info and Guides

Adobe Acrobat FileSingle and Multi Split Systems 2012 Catalog

You will need Adobe Acrobat Reader to view and print pdf files

Adobe Reader
Product Reviews
Warranty Info

Warranties on mini split air conditioners only include parts and do not include labor. The licensed HVAC Technician who installs your air conditioner should always provide you with a labor warranty (preferably for at least a full year to compliment the manufacturers' parts warranty).

AJ Madison will only finalize a Mini Split (Ductless Split System) purchase with an authorized HVAC Technician. AJ Madison recommends the installation of a mini-split system to be performed by a trained and qualified HVAC technician with the proper knowledge and background. A trained technician will be able to judge the best location for the air handling (evaporator) unit and also the correct size for the area the unit will heat and/or cool. For assistance with all your technical needs please contact our technical department at hvactechsupport@ajmadison.com.

Should you experience an issue during the installation or the initial startup of a unit please do not contact the manufacturer. You should have the technician that installed your system contact either AJ Madison or the manufacturer. We cannot accept any service or warranty calls from anyone but a licensed HVAC technician. We have a full technical support team available to help you throughout the installation process.

AJ Madison, Inc. cannot be held liable for improper installation and operation of any product purchased from our company. Should a warranty issue arise in which parts will need to be replaced, an installation receipt will be required along with your AJ Madison sales receipt. Failure to provide a receipt or invoice may result in the warranty not being honored.

Items to Compare

Quick LookQuick Look

Quick Specs
Quick Specs

General

  • AC System Type : Mini Split
  • Component Type : System
  • Operation : Cooling with Heat Pump
  • No. of Rooms : 1
  • Min No. of Connectible Indoor Units : 1
  • Max No. of Connectible Indoor Units : 1
  • Indoor Unit Placement Type : Wall Mount
  • Wireless Remote Control(s) Included : Included
  • Wired Remote Control(s) Included : Optional

Capacity

  • BTU Class : 24,000 BTU
  • Heating Capacity : 29,000 BTU

Electrical Data

  • Running Current Cooling - Max. (Amps) : 10.8 Amps
  • Running Current Heating - Max (Amps) : 12 Amps
  • Power Input Cooling - Max. (Watts) : 2,460 Watts
  • Power Input Heating - Max. (Watts) : 2,490 Watts

Performance

  • Energy Star Certified : No
  • EER (Energy Efficiency Rating) : 9.8
  • SEER (Seasonal Energy Efficiency Rating) : 17
  • Airflow Rate Medium (CFM) : 659 CFM

Refrigeration System

  • Max. Line Length - Each : 100 Ft.

Technical Details

  • ADA Compliant : No
Are you a builder