SANYO: Your Best Choice in Ductless Split Air Conditioning Systems
Sanyo's Ductless Split Air Conditioner & Heat Pump products offer wide versatility in solving your cooling and heating requirements. The Indoor unit (evaporator) is mounted inside the room, enclosed in a handsome space saving cabinet. It is connected to the outdoor unit (condenser) via refrigerant lines & inter-unit wiring through a 3-1/2" opening in the wall. Since no ductwork is required, installation is simple, fast & efficient. There is no need to use up window space or cut large openings in existing walls, which could undermine the integrity of your structure, and even pose security risks. Since the Rotary compressor is located in the outdoor unit, compressor operating noise is virtually eliminated from the indoor. The indoor unit has been uniquely designed to provide Whisper Quiet operation while delivering comfort throughout the room(s). In addition, rotary compressors provide efficient, powerful cooling at the lowest noise levels in the industry.
DC INVERTER is outstanding for it's RAPID COOLING & HEATING POWER. As soon as the temperature is reached, it automatically adjusts current frequency temperature fluctuation. It also provides "ENERGY-SAVING" (which saves your electricity charges) as well as "QUIETER OPERATION".
A ductless split unit must be installed by a licensed HVAC (Heating ventilation air conditioning) Contractor.
Warranty Info
Luxuries Of A Mini-Split (Ductless Split System)
Ductless Split Air Conditioner and Heat Pump products offer wide versatility in solving your cooling and heating requirements. The Indoor unit (evaporator) is mounted inside the room, and usually goes very unnoticeable. It is connected to the outdoor unit (condenser) via refrigerant lines and inter-unit wiring through a 3-1/2" opening in the wall. Since no ductwork is required, installation is simple, fast and efficient. There is no need to use up window space or cut large openings in existing walls, which could undermine the integrity of your structure, and even pose security risks. Since the Rotary compressor is located in the outdoor unit, compressor operating noise is virtually eliminated from the indoor. The indoor unit has been uniquely designed to provide Whisper Quiet operation while delivering comfort throughout the room(s). In addition, rotary compressors provide efficient, powerful cooling at the lowest noise levels in the industry.
Installation and Warranty Info
AJ Madison recommends the installation of a Ductless Split System to be done by a trained and qualified HVAC technician with the proper knowledge and background. A trained technician will be able to judge the best location for the air handling (evaporator) unit and also the correct size for the area it has to cool. For assistance with all your technical needs please contact our technical department at hvactechsupport@ajmadison.com.
Note: AJ Madison will only finalize a Mini-Split (Ductless Split System) purchase with an authorized HVAC Technician.
Should you experience an issue during the installation or the initial startup of the unit please do not contact the manufacturer. You should have the technician that installed the units contact either AJ Madison or the manufacturer. We cannot accept any service or warranty calls from anybody but a licensed HVAC technician. We have full technical support team available to help you throughout the installation process.
AJ Madison, Inc. cannot be held liable for improper installation and operation of any product purchased from our company. Should a warranty issue arise where parts will need to be replaced, an installation receipt will be required along with your AJ Madison sales receipt. Failure to provide a receipt or invoice may result in the warranty not being honored.
Note: Warranties on mini split air conditioners only include parts and do not include labor. The licensed HVAC Technician who installs your air conditioner should always provide you with a labor warranty (preferably for a full year to compliment the manufacturers' parts warranty).
| Unit Model No. |
| Indoor Unit: |
KHS1872 |
| Outdoor Unit: |
CH1872 |
| Indoor Unit Dimensions & Weight |
| Height: |
11 23/32" |
| Width: |
41 15/16" |
| Depth: |
8 19/32" |
| Net Weight: |
26.5 lbs. |
| Outdoor Unit Dimensions & Weight |
| Height: |
26 3/8" |
| Width: |
34 21/32" |
| Depth: |
11 7/32" |
| Net Weight: |
97.0 lbs. |
| Performance & Electrical Ratings |
| Capacity - Cooling: |
17,500 (4,000~17,500) BTU/h |
| Capacity - Heating: |
20,400 (4,400~20,400) BTU/h |
| Moisture Removal - High: |
4.89 Pints/H |
| Dry Air Flow - Hi/ Med/ Low: |
524/ 479/ 417 CFM |
| SEER - Cooling: |
20.0 |
| HSPF - Heating: |
7.7 |
| COP - Heating: |
N/A |
| Power Supply: |
230/208 Volts, 1 Phase, 60 Hz |
| Running Amps - Cooling: |
7/7.7 (1.2~7.7) Amps |
| Running Amps - Heating: |
7.4/8.1 (1.3~8.1) Amps |
| Power Input - Cooling: |
1,500/1,500 (250~1,500) Watts |
| Power Input - Heating: |
1,575/1,575 (270~1,575) Watts |
| Back-up Heater (kW): |
N/A |
| Fuse or Circuit Breaker Capacity: |
20 Amps |
| Features |
| Controls: |
Microprocessor |
| Low Ambient Control: |
N/A |
| Wireless Remote Controller: |
Included |
| Fan Speeds: |
Hi/ Med/ Low & Auto |
| Timer: |
1 hr OFF and 24-hr PROGRAM |
| Air Deflection - Horizontal: |
Manual |
| Air Deflection - Vertical: |
Automatic |
| Air Filter: |
Washable |
| Refrigerant: |
R-410A |
| Refrigerant Control: |
Electric Expansion Valve |
| Operation Sound - In (Hi/ Med/ Low/ Qt): |
42/ 38/ 30/ 28 dB-A |
| Operation Sound - Outdoor (Hi): |
51 dB-A |
| Refrigerant Piping - Type: |
Flare Type |
| Refrigerant Piping - Discharge: |
1/4" Discharge |
| Refrigerant Piping - Suction: |
1/2" Suction |
| Refrigerant Pipe Length: |
Max. 98 ft. |
| Elevation Difference - Outdoor Above: |
Max. 50 ft. (This is the maximum elevation difference when the indoor unit is located above the outdoor unit.) |
| Elevation Difference - Outdoor Below: |
Max. 50 ft. (This is the maximum elevation difference when the indoor unit is located above the outdoor unit.) |
| Operation Range of Heat Pump Unit |
| Max. Temperature (Cooling) - Indoor Air Intake: |
95°F DB/ 71°F WB |
| Max. Temperature (Cooling) - Outdoor Air Intake: |
115°F DB |
| Min. Temperature (Cooling) - Indoor Air Intake: |
67°F DB/ 57°F WB |
| Min. Temperature (Cooling) - Outdoor Air Intake: |
50°F DB |
| Max. Temperature (Heating) - Indoor Air Intake: |
80°F DB/ 67°F WB |
| Max. Temperature (Heating) - Outdoor Air Intake: |
75°F DB/ 65°F DB |
| Min. Temperature (Heating) - Indoor Air Intake: |
-°F DB/ -°F WB |
| Min. Temperature (Cooling) - Outdoor Air Intake: |
0°F DB |
- The unit operates at maximum capacity by pressing a High Power Mode button.
- The DC Inverter Air Conditioner affords continuous operation, while it adjusts capacity according to the room temperature.
- The accurate sensing of cooling or heating loads prevents frequent changes in capacity and ensures efficient, economical operation.
- The DC Inverter Air Conditioner uses a twin rotary compressor. Compared to the conventional single cylinder type, the twin rotary compressor dramatically reduces vibration and noise during operation, thus ensuring quiet operation.
- With the integration of inverter technology and R-410A refrigerant, Sanyo's products meet the DOE of a minimum requirement of 13 SEER.
- ODP (Ozone Depletion Potential) = 0 of HFC refrigerant is used.
- Since the DC Inverter Air Conditioner has efficient rapid heating and cooling capacity produced by variable compressor rotation speed, it ensures quicker control of room temperatures than conventional air conditioners.
- Microprocessor control ensures that the temperature and humidity levels in the room are always comfortable.
- Sanyo's infrared Remote Control with an easy to read LCD Display, gives the user the capability to adjust & set: temperature, sweep (louver control), fan speeds, timer, night setback and more, for complete automatic operation.
- By coupling compressor and fan operation, intermittent operation can be precisely controlled according to room temperature, so that air is efficiently dehumidified.
- Convenient microprocessor control automatically adjusts fan speed to High, Medium or Low, according to room temperature to maintain a comfortable airflow throughout the room.
- The air sweep function moves the louver up and down in the air outlet, directing air in a "sweeping" motion around the room and providing comfort in every corner.
- Louver can be manually set to the desired angle by remote control.
- The negative ions generator fills your room with negative ions throughout the year.
- Ion generating power - over 100,000 parts/cc
- When this button is pushed either while the unit is operating or while it is stopped, the unit will operate for one hour and then switch off automatically.
- The remote control unit allows you to set a wide variety of timer-based operations.
- Such functions include automatic ON/OFF with a timer setting, same time ON/OFF every day, ON timer, OFF timer and Combination Timer.
- Cooling and DRY mode
- With the Night Setback Mode, the air conditioner automatically raises the setting temperature 2° after 30 minutes.
- and then another 2° after the next 30 minutes.
- Heating Mode:
- With the Night Setback Mode, the setting temperature is automatically lowered 4° after 30 minutes
- and then another 4° after the next 30 minutes.
- this saves energy without sacrificing comfort and is ideal for gentle cooling and heating.
- This feature allows the system to automatically resume operation at its preset program, after power is restored from a power failure.
- Apatite or calcium phosphate is highly effective in trapping germs, mites and mite excrement, pollen, dirt and dust, and cigarette odor.
- The triple layered air clean apatite filter consists of antibacterial, deodorizing, and dust-collecting sections that maintain healthy, clean air in your room.
- Filter is treated with anti-mold chemicals to prevent mold or bacteria from occurring.
- The circulation volume of the refrigerant is controlled by a pulse type electric control valve.
- In order to attain optimum efficiency, when the power is switched ON, the opening degree of the electric control valve is controlled between 90 and 480 steps. (Ceiling Recessed Models Only)
- Every low fan speed for extra quiet operation.
- Details of previous warnings are stored and can be verified on the liquid crystal display.
- This makes it easier to diagnose malfunctions, greatly reducing service labor. (Wired remote controller)
This product has not been reviewed.
Luxuries of a Mini-Split (Ductless Split System)
Ductless Split Air Conditioner & Heat Pump products offer wide versatility in solving your cooling and heating requirements. The Indoor unit (evaporator) is mounted inside the room, and usually goes very unnoticeable. It is connected to the outdoor unit (condenser) via refrigerant lines & inter-unit wiring through a 3-1/2" opening in the wall. Since no ductwork is required, installation is simple, fast & efficient. There is no need to use up window space or cut large openings in existing walls, which could undermine the integrity of your structure, and even pose security risks. Since the Rotary compressor is located in the outdoor unit, compressor operating noise is virtually eliminated from the indoor. The indoor unit has been uniquely designed to provide Whisper Quiet operation while delivering comfort throughout the room(s). In addition, rotary compressors provide efficient, powerful cooling at the lowest noise levels in the industry.
Installation & Warranty Info
AJ Madison recommends the installation of a Ductless Split System to be done by a trained and qualified HVAC technician with the proper knowledge and background. A trained technician will be able to judge the best location for the air handling (evaporator) unit and also the correct size for the area it has to cool. For assistance with all your technical needs please contact our technical department at hvactechsupport@ajmadison.com.
Note: AJ Madison will only finalize a Mini-Split (Ductless Split System) purchase with an authorized HVAC Technician.
Should you experience an issue during the installation or the initial startup of the unit please do not contact the manufacturer. You should have the technician that installed the units contact either AJ Madison or the manufacturer. We cannot accept any service or warranty calls from anybody but a licensed HVAC technician. We have full technical support team available to help you throughout the installation process.
AJ Madison, Inc. cannot be held liable for improper installation and operation of any product purchased from our company. Should a warranty issue arise where parts will need to be replaced, an installation receipt will be required along with your AJ Madison sales receipt. Failure to provide a receipt or invoice may result in the warranty not being honored.
Note: Warranties on mini split air conditioners only include parts and do not include labor. The licensed HVAC Technician who installs your air conditioner should always provide you with a labor warranty (preferably for a full year to compliment the manufacturers' parts warranty).
|